  1.                          SECTION 04813
  2. NOTE ** Note:  This section could also be classified as a
  3.         skylight system in Division 8 under Section 08630 -
  4.         Metal-Framed Skylights.
  5.  
  6.     GLASS BLOCK SKYLIGHT SYSTEM
  7.  
  8. NOTE ** This section is based on the "IBP Glass Block Grid
  9.         System" manufactured by Innovative Building
  10.         Products, Inc., headquartered at the following
  11.         address:
  12. NOTE **      2917 W. 7th Street
  13. NOTE **      Fort Worth, TX  76107
  14. NOTE **      Telephone: (800) 932-2263
  15. NOTE **      Fax: (817) 332-1406
  16. NOTE **
  17. NOTE ** SECTION 04813 - GLASS BLOCK SKYLIGHT SYSTEM,
  18.         Copyright 1996-97, The Architect's Catalog, Inc.
  19.  
  20. PART 1  GENERAL
  21.  
  22. 1.1 SECTION INCLUDES
  23. NOTE ** Delete items below not required for project.
  24.  
  25.     A.  Glass block skylight system, consisting of extruded
  26.         aluminum grid and glass blocks, and with all other items
  27.         necessary for a complete assembly, mounted on curb.
  28.  
  29.     B.  Glass block skylight system, consisting of extruded
  30.         aluminum grid and glass blocks, and with all other items
  31.         necessary for a complete assembly, mounted on separate
  32.         structure.
  33.  
  34. 1.2 RELATED SECTIONS
  35. NOTE ** Delete any sections below not relevant to this
  36.         project; add others as required.
  37.  
  38.     A.  Section 07600 - Flashing and Sheet Metal.
  39.  
  40. 1.3 REFERENCES
  41. NOTE ** Delete references from the list below that are not
  42.         actually required by the text of the edited
  43.         section.
  44.  
  45.     A.  ASTM B 221 - Standard Specification for Aluminum and
  46.         Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and
  47.         Tubes.
  48.  
  49. 1.4 SUBMITTALS
  50.  
  51.     A.  Submit under provisions of Section 01300.
  52.  
  53.     B.  Product Data:  For both grid system and glass block.
  54.         Indicate materials, sizes, shapes, thicknesses, and
  55.         finishes.  Include installation and assembly
  56.         instructions.
  57. NOTE ** Retain shop drawings for custom designed units and
  58.         for other installations where shop drawings would
  59.         confirm that the manufacturer and contractor have
  60.         interpreted the contract documents correctly.
  61.  
  62.     C.  Shop Drawings:  Show methods of construction, location
  63.         and spacing of anchors, and relationship to adjoining
  64.         work.
  65. NOTE ** Delete selection samples if colors and patterns are
  66.         specified.
  67.  
  68.     D.  Selection Samples:  Manufacturer's full range of finishes
  69.         and colors, for selection.
  70.  
  71. 1.5 DELIVERY, STORAGE, AND HANDLING
  72.  
  73.     A.  Store materials in dry place, off the ground, where
  74.         temperature will not exceed 90 degrees F (32 degrees F).
  75.  
  76.     B.  Handle material in manner that will prevent damage to
  77.         finished surfaces.  Do not install scratched or damaged
  78.         components.
  79.  
  80. 1.6 WARRANTY
  81.  
  82.     A.  Provide manufacturer's standard warranty.
  83.  
  84.     B.  Provide one year installer's warranty against faulty
  85.         workmanship and water leakage.
  86.  
  87.  
  88. PART 2  PRODUCTS
  89.  
  90. 2.1 MANUFACTURERS
  91.  
  92.     A.  Glass Block Support Grid:  Provide "IBP Glass Block Grid
  93.         System" manufactured by Innovative Building Products,
  94.         Inc., 2917 W. 7th Street, Fort Worth, TX 76107. ASD.
  95.  
  96.     B.  Glass Block:  Provide products manufactured by one of the
  97.         following:
  98. NOTE ** Coordinate the list of glass block manufacturers
  99.         with those who can make block of the type (pattern,
  100.         color, thickness, etc.) that are required.
  101.         1.  Pittsburgh Corning Corp.
  102.         2.  Westerwald Glasstein (Solaris).
  103.         3.  Glashaus Inc. (Weck).
  104.  
  105. 2.2 MATERIALS
  106.  
  107.     A.  Glass Block Support Grid:  Factory assembled, extruded
  108.         aluminum two-way T-bar grid, sized to fit glass block
  109.         with one block to a module, and hollow perimeter frame
  110.         with predrilled fastener holes.
  111.         1.  Aluminum:  ASTM B 221, 6063-T6 or 6463-T6 alloy.
  112.         2.  Finish:  As selected by Architect from manufacturer's
  113.             standard finishes.
  114.  
  115.     B.  Glass Block:  Partially evacuated hollow units, 7-3/4
  116.         inches (196 mm) square by 3-1/8 inches (79 mm) thick.
  117. NOTE ** Enter the manufacturer's pattern name in the blank.
  118.         1.  Pattern:  ___________.
  119. NOTE ** Select one of the following color paragraphs.
  120.         Enter a color description in the blank.
  121.         2.  Color:  Clear.
  122.         3.  Color:  __________.
  123.  
  124.     C.  Foam Tape:  Adhesive backed, closed cell foam, 1/16 inch
  125.         (1.5 mm) or 3/32 inch (2.5 mm) thick.
  126.  
  127.     D.  Sealant:  Dow Corning Corp. "TradeMate" glass block
  128.         sealant.
  129.  
  130.     E.  Fasteners for Attaching Skylight Frame to Curb:
  131.         Tamperproof, cadmium plated.
  132.  
  133.     F.  Accessories:  Provide all sealants, flashings, anchors,
  134.         fasteners, and other items necessary for complete weather-
  135.         and waterproof installation.
  136.  
  137.  
  138. PART 3  EXECUTION
  139.  
  140. 3.1 EXAMINATION
  141.  
  142.     A.  Verify applicable field dimensions and adjust as
  143.         necessary to accommodate frame.
  144.  
  145.     B.  Examine curb and supporting structure and correct any
  146.         conditions that are not in accordance with manufacturer's
  147.         installation instructions.
  148.  
  149. 3.2 INSTALLATION
  150.  
  151.     A.  Install grid system and glass block according to
  152.         manufacturer's instructions.
  153.  
  154.     B.  Apply continuous sealant bead on top of curb.
  155.  
  156.     C.  Place frame on curb and press down to seat properly and
  157.         overlap flashings.  Fasten frame in place securely.
  158.  
  159.     D.  Adhere foam tape to entire perimeter of each glass block
  160.         and insert glass block into grid from exterior side so
  161.         that block is pressed against T-bar without rolling back
  162.         foam tape.
  163.  
  164.     E.  Apply sealant around exterior face of glass block
  165.         completely filling channel.  Tool sealant flush with
  166.         surface.
  167.  
  168.     F.  Apply sealant to corner caps.
  169.  
  170. 3.3 CLEANING
  171.  
  172.     A.  Clean exposed surfaces of aluminum grid with clean, soft
  173.         cloth and mild hand soap using gentle rubbing action.  Do
  174.         not use abrasive or solvent type cleaners, detergents, or
  175.         paint removers.
  176.  
  177.     B.  Remove labels from glass block and clean with soft cloth
  178.         and water.
  179.  
  180. 3.4 PROTECTION
  181.  
  182.     A.  After installation, protect installed work from damage
  183.         caused by subsequent operations at project site.
  184.  
  185.  
  186.                          END OF SECTION